Input Process Parameters

In this task, you set up and run the cooling analysis.

  1. Click Home > Molding Process Setup > Analysis Wizard.

  2. Uncheck Fill.

  3. Check Cool.

  4. Click Next.

  5. Confirm the material is Styron EUR Magnum 3416 SC, then click Next twice to get to the Advanced tab.

  6. Enter 25 seconds as the Injection + Packing + Cooling time.

  7. Click Analyze to start the analysis.

    The analysis takes several minutes to analyze.

When the analysis is finished, click Summary to close the Summary panel