Use the Dalton Browser to set the system properties, as well as the boundary conditions for the system, and the elements properties.
Set the calculation method for minor losses, and the fluid used in the system.
Minor losses depend on various factors such as sudden changes in the pipe diameter, bending angles, or valves.
There are three calculation methods for minor losses:
This is the default method. Minor losses are calculated automatically unless a K factor has been defined. If k factors have been supplied, Dalton uses them to calculate the minor losses.
If this option is selected, the provided K factors are used to calculate minor losses.
If this option is selected, minor losses are calculated and added to the specified K factors.
The fluid density may vary in response to changes in the fluid temperature and pressure.
A boundary node is a node that is connected to one element. You must specify boundary conditions for at least one inlet and one outlet.
Pressure, velocity, mass flow rate and Reynolds number are typical boundary conditions.
When solving pipe networks, at least one boundary condition in the network needs to be a pressure boundary condition.
You can use the default fluid temperature, or specify one.
Elements are assigned a set of properties which depends on their type.
You can modify these properties in the Dalton Browser.
The friction factor depends on the Reynolds number in the fluid and the relative roughness of the pipe or duct material.
The roughness depends on the type of material used for the element.
The pump curve represents the pressure rise flow rate relationship through the pump or fan.
This value is used to define the efficiency at which the pump is operating at.
The Generic losses vary with the pipe diameter, surface roughness, Reynolds number and the geometry of the design.