Variables

Specify any of the following variables.

CONFIGURATION The configuration name is used as the root folder for configuration folders (Annotations, Blocks, Material, and Style). This name is used if you save the configuration. The configuration name should be short, abbreviated, with no spaces. For more information about sharing configurations, see To Share Configuration.
DIVDIST This value is used in calculating the clearance above the ground or the clearance between wires.
HOUSEHT Specify the default attachment height of the service line at the service point. This value specifies the height at which the service line is attached at the customer's service point.
HSEKW Specify the default load value for service point features. Select the units of choice and enter the value. Service point load value is used by the Voltage Drop analysis.
MOTLOAD Specify the default Motor Load value for service point features. Select the units of choice and enter the value. Motor Load value is used by the Voltage Drop analysis.
RULELOGGING To create a log output of rule executions, set the Value parameter to True. The log is created in the same directory as the DWG file (or the .DWT location if the new drawing has not yet been saved). The log file name is the same as the drawing file, but with a .LOG extension.
SERVPTDIST Specify the default service point distance from the stub when using automatic service point generation to draw future service lines with stubs.
STLTLOAD Specify the default load value for Streetlight features. Select the units of choice and enter the value. Streetlight Load value is used by the Voltage Drop analysis.
SymbolScale For Value, specify the amount to scale symbology in the design drawing. You can also set this value on the Home tabData paneldown arrow.