About the Set Pipe End Location Rule

This rule allows you to set the start and end locations of the pipes to be at the structure centre or at an offset relative to the structure's inner or outer wall. It also includes an option to specify whether to hold the pipe slope or pipe invert when moving the pipe end location with this rule.

By default, when Autodesk Civil 3D pipes connect to structures, they connect at the centre of the structure. When using the Set Pipe End Location rule, you can specify that the start and end locations of the pipes are located at the structure centre or at a specified offset relative to the structure's inner or outer wall. The start and end locations of the pipes will be shown in plan and profile views at these specified locations. Grips for the pipes will also appear at these locations. The length values for the pipes will be measured from the start location to the end location that are specified by this rule.

Note: When structures are moved, the Autodesk Civil 3D behaviour is to reconnect attached pipes to the structures. The pipes will still default to the structure centre and you will need to use the Apply Rules command in order to reset the pipe end locations.

Parameters