Junction nodes are points placed at the intersection of two or more pipes (intersections or tees). Junctions are used to represent points of water consumption or inflow, points where specific analysis values (e.g., pressure, concentration) are desired, and at points where pipe attributes (e.g., diameter, material) change. Junction nodes must have their elevation above datum (e.g., sea level) specified in order for pressure computations to be meaningful.
This page contains the following topics:
- Create a Junction
- Edit a Junction
- Edit the data for a group of Junctions
- Delete a Junction
- Recall a deleted Junction
Create a Junction
To create a junction node, do the following:
Click on the InfoWater Pro Ribbon in the Edit Group using the → Insert Command dropbox
.
Select the Insert Junction icon from the Insert Command dropbox
.
When the Insert
Junction command is the active command it will be highlighted in Blue as shown:
.
Once the command is initiated, select the location of the new node by clicking anywhere on the map display. Suggest a new ID and/or a description on the Junction Identification dialog box and click OK to accept the ID and create the junction. The junction should visually appear at the specified location. If the insert location is near an existing model pipe, the software will prompt you to insert the junction into that pipe. If you wish to split the pipe, the Junction Identification dialog box for the new junction and the new pipe will appear in a pop-up window.
You can also use the
Digitize Network icon
from the
→ Insert Command dropbox to create a pipe and node network on the fly. Once digitized, you are able to add relevant modeling data in the
Model Explorer - Attribute
Tab window or via the
DB Editor.
Edit a Junction
Graphic Selection - To select a junction node for data edit do one of the following:
Choose the Select icon
from the
Model Explorer - Attribute Tab
window and click on the specific Junction or select the InfoWater Pro Ribbon in the Edit Group using the → Select icon
.
If a Junction has been prior selected and is a part of the Browse history, it can be re-selected by choosing it from the Browse-History section of the Model Explorer - Attribute Tab window.
Data Edit - To edit the data related to a junction, first select the junction using the tools above. Once selected, edit Junction related data by adding/modifying the fields in the Model Explorer - Attribute Tab window. Additionally modifications may be done by editing the DB Tables that may be accessed from the
InfoWater Pro Ribbon in the Edit Group using the → DB Editor
icon
.
Graphic Edit - To edit the node graphically do one of the following: From the InfoWater Pro Ribbon in the Edit Group using the → Edit Command dropbox
icon
select the
Move Node command
from the drop-down menu list. Click on the mouse and hold the left click down on the junction to select it. With the junction is highlighted, move the node to the desired position and left mouse click. Once in the desired location, release the left mouse button and the node location will be updated to the new location.
When the Move Node command in the
InfoWater Pro Ribbon in the Edit Group → Edit Command dropbox is the active command it will be highlighted in Blue as shown:
.
If you have not enabled the
Auto Length Calculation checkbox
from the
InfoWater Pro Ribbon in the Project Group using the
Preferences
icon
and the
Operations
tab, all pipes connected to a node moved will not have their lengths automatically changed.
Edit the data for a group of Junctions
Group edits can be made by either creating a domain or by creating a selection.
Using the Domain Manager - Create a domain selecting the specific junctions that you want to edit. Refer to the section on
Domain Manager
for details on the domain creation process. Once the domain has been created, choose the InfoWater Pro Ribbon in the Edit Group using the → DB Editor icon
. Depending on the data you want to edit choose the appropriate table type from among the different database tables. Choose
as the
Data Scope and click on
OK.
Using the User Selection - Select choose the InfoWater Pro Ribbon in the Edit Group using the → DB Editor icon
. Depending on the data you want to edit choose the appropriate table type from among the different database tables. Choose as the
Data Scope and choose the
User Selection
command. This places the software in User Selection Mode. In InfoWater Pro, the Selected elements will be in a
cyan
color. Once all of the desired junctions are selected,
right click and choose
Enter to access the DB Tables for the selected junctions.
Once the specific tables have been opened with the desired scope, enter data one cell at a time or Block Edit data to make changes in bulk to multiple cells.
Group Editing for certain specific features may also be done by choosing the
Group Editing
icon
or the
Edit Domain icon
under the
InfoWater Pro Ribbon in the
Edit Group . Refer to the sections on
Group Editing and
Edit Domain to learn more.
Delete a Junction
To delete a junction, select the
Delete Node option
in the
InfoWater Pro Ribbon in the
Edit Group
→ Edit Command dropbox.
Select the node to be deleted and InfoWater Pro prompts you to confirm deletion (if the
Delete Confirmation checkbox
is checked in the Operation Settings tab in the
Preferences
settings
.
The active selected junction in the Model Explorer - Attribute Tab window may also be deleted by selecting the Delete icon
with the InfoWater Pro prompt to confirm element deletion.
All pipes attached to the Junction being deleted will also be deleted if the
Auto Pipe Delete checkbox
is checked in the
Operation Settings tab in the
Preferences
settings
. The Junction and associated pipes are deleted and saved in the InfoWater Pro recycle bin and can be recalled from the database using the
Model Explorer - Command Center Tab from the
Utilities - > Recall (node or Pipe) command. However, if
Auto Database Packing
is checked (Operation Settings tab in the
Preferences
settings
), then any element deleted is permanently deleted from the database and cannot be recalled. Deleted elements can be recalled until the
Pack and then
Clean commands (found in the
Model Explorer - Command Center Tab from the
Utilities → Database
menu list) are completed which removes deleted element ID's from the database.
Recall a deleted Junction
To recall a deleted junction, go to Model Explorer - Command Center Tab, then go to Utilities - > Recall, and select the Node command. In order to perform the recall, you must know the ID of the junction that was deleted. You may choose the Show Deleted Node command to obtain a list of nodes deleted from the InfoWater project but saved in the InfoWater recycle bin. Deleted elements can be recalled until the Pack and then Clean commands (found in the Model Explorer - Command Center Tab under Utilities → Database menu list) are completed which removes deleted element ID's from the database permanently.