Project Admin Introduction

Projects enable teams to manage access to cloud databases through membership and permissions. Each account with cloud databases of InfoWorks ICM, InfoWorks WS Pro, InfoWater Pro, and InfoDrainage is structured with the following four layers:

  • Team: The Team is where licensing is managed from manage.autodesk.com for all users within a customer account.
  • Hub: A Hub is a deployment of Info360 cloud services within a selected Region. Only Team Admins can create Hubs. Members with Hub Admin Access can manage members of the Hub and create Projects.
  • Project: Each Hub can contain many Projects, which are used to group together databases and manage the members that can access the data. Only Project Admins can access the Project Admin page to edit the list of Project Members.
  • Database: Databases and their contents are managed from InfoWorks ICM, WS Pro and Info360 Model, which can be used to move databases from one Project to another.

For more information about Project Administration, go to the Administration Guide.

Role-based Permissions

For a user to access a cloud database in a Project, the user must be a member of the Project, and they must have an assigned Role of Model Editor or Model Reader. There is an exception where Admins of the Project are automatically treated with Model Editor permissions.

Note: The two Roles of Model Editor and Model Reader are automatically added to each Hub created for Info360 and should not be deleted or modified.

The table below outlines several potential permissions and access levels depending on varying configurations of licensing, Role, and Access Level.

User

User 1

User 2

User 3

Licenses Assigned

ICM, WS Pro

ICM

No license

Team A Projects

Project 1

Project 2

Project 1

Project 2

Project 1

Project 2

Project Access Level

Admin

Admin

Member

Member

Admin

Member

Project Role

(ignored)

(ignored)

Editor

Reader

(ignored)

Editor or Reader

Access to Project Admin

Yes

Yes

No

No

Yes

No

Access using Info360 Model

Admin

Admin

Editor

Read Only

Admin

Read Only

Access using ICM

Editor

Editor

Editor

Read Only

None

None

Access using ICM Viewer

Viewer

Viewer

Viewer

Read Only

Read Only

Read Only

Access using WS Pro

Editor

Editor

None

None

None

None

Access using WS Pro Viewer

Viewer

Viewer

Viewer

Read Only

Read Only

Read Only

ICM versions 2026.1 and older

Editor

Editor

Editor

Read Only 2

None

None

ICM Viewer 2026.1 and older

Viewer

Viewer

Viewer

Read Only 2

None 1

None 1

WS Pro versions 2026.1 and older

Editor

Editor

None

None

None

None

WS Pro Viewer 2026.1 and older

Viewer

Viewer

Viewer

Read Only 2

None 1

None 1

1 Desktop client versions 2026.1 and earlier require an Info360 Model entitlement, so no access is allowed without a license.

2 Desktop client versions 2026.1 and earlier do not support the Read-Only permissions enforced by the cloud. Attempts to edit forbidden objects will result in error messages.

The varying access levels for desktop clients are defined as the following:

  • Editor: Full editing permissions to cloud databases, including running simulations.
  • Read Only: The user can view all data as read-only. This allows copying and exporting of data, but no editing or simulations.
  • None: Either no access to the software without a license, or no access to data in the Project if no Role is assigned.
  • Viewer: This is a hybrid state based on legacy behavior of InfoWorks Viewers where some limited editing of data is allowed as defined on the WS Pro Free Viewer page.

The permissions for varying tasks within Info360 Model are outlined in the table below:

Task Admin Editor Reader
Delete database

Yes

No

No

Restore database

Yes

No

No

Move database

Yes*

No

No

Cancel Run

Yes

Yes

No

Note: To move a database between two projects, the Admin must have at least Model Editor permissions in the destination Project.
Note: For InfoDrainage, a user needs Admin or Editor role to submit a simulation/analysis. A user with a Reader role cannot run simulation and is thrown with error.

Was this information helpful?