Some Synergi objects are imported as more complex InfoWorks objects, and additional data will be required to completely define these InfoWorks objects.

General Notes

Note: To import Synergi data, you need at least version 4.3 of Synergi (versions 4.3 to 4.7 are supported).
Due to differences between InfoWorks WS and Synergi data models, a number of adjustments are made during the import process:
  • Synergi node and link names have a length of 32 characters. InfoWorks WS node names are restricted to 30 characters. The importer will truncate names over 30 characters in length.
  • Synergi labels are not imported.
  • Synergi scripts are not imported.
  • Synergi pump types HP and QH are not imported.
  • Synergi can include assets in the model that are marked as inactive. All elements in the Synergi model are imported into the InfoWorks network. Active elements are saved in a selection list which is included in the InfoWorks run object. Inactive elements are therefore excluded from the run by default.

Run Settings

The settings on the Schedule Hydraulic Run View are set to the following:

Run Schedule Value
Start date Analysis Date from Synergi
Start time 00:00
End date/time Start date/time + 1 day
Time step Time Step Size from Synergi
Computational accuracy 1 l/s
Disconnected System Set to Checked
Simulation Options: Stop outflow from em pty reservoirs Set to YES
Simulation Options: Enforce Value/PST regulation tolerance Set to YES

Pipes

IWWS Data Field Values imported from Synergi
From Node Name of Pipe From Node
To Node Name of Pipe To Node
Link Suffix Suffix added by InfoWorks for each parallel pipe.
Asset ID Pipe Name from Synergi
Diameter

Pipe Diameter

For MN (Manning) conduits, Diameter = 4 x Hydraulic Radius.

Length

Pipe Length

For HE pipes, the equivalent length of minor losses is added to the pipe length.

Friction Type Set to:
  • CW for DW pipes and non-zero roughness.
  • DW for DW pipes with zero roughness and MN pipes.
  • HW for HW and HE pipes.
Darcy Weisbach

Set for DW pipes. For MN (Manning) conduits, the conduit is converted to a circular pipe with diameter = 4 x hydraulic diameter.

The Mannings roughness coefficient is converted to a Darcy Weisbach friction factor.

Roughness Only set if roughness in Synergi is non-zero.
Hazen Williams Set for HW pipes.
Notes Element Description from Synergi.

Valves

IWWS Data Field Values imported from Synergi
From Node Name of Valve From Node
To Node Name of ValveToNode
Link Suffix Suffix added by InfoWorks for each parallel pipe.
Asset ID Valve name from Synergi.
Length Set to default value by InfoWorks: 1.0m
Diameter Valve or Regulator Diameter
Friction Type Set to default value by InfoWorks: DW
DW - f Set to default value by InfoWorks: 0.015
Valve Diameter Valve or Regulator Diameter
Loss Coeff. (Open) Valve Coefficient
Valve Curve Set by InfoWorks to:
  • GATE if Loss Coeff=0.0001 and the valve is fully open or fully closed.
  • PLUG otherwise.

Mode ID

(control data)

Set by InfoWorks to:
  • THV for Synergi VL valves.
  • TCV for Synergi VV valves.
  • PRV for Synergi VP valves if the control node is the To node.
  • PSV for Synergi VP valves if the control node is the From node.
  • FRV for Synergi VF valves.

Opening (%)

(control data)

Valve Tau is converted to opening.

Pressure

(control data)

Regulator pressure; set for VP valves.

Flow

(control data)

Regulator flow; set for VF valves.

Control Node

(control data)

Set for VP valves.

Regulation Precision

(control data)

Set to default value by InfoWorks: 0.1
Notes Element description.

Non-return valves

IWWS Data Field Values imported from Synergi
From Node Name of Valve From Node
To Node Name of Valve To Node
Link Suffix InfoWorks adds a suffix for each parallel lin.
Asset ID Valve name from Synergi
Local Loss Coefficient Valve Coefficient
Length Set to default value by InfoWorks: 1.0m
Diameter Valve Diameter
Friction Type Set to default value by InfoWorks: DW
DW - f Set to default value by InfoWorks: 0.015
Non Return Valve Diameter Valve Diameter
Notes Valve Element Description

Float Valves

Note that profiles are not imported. IWWS substitutes its own internal profile curve.

Valves on reservoir links are converted to float valves in InfoWorks to prevent reservoir overtopping.

IWWS Data Field Values imported from Synergi
From Node Element From Node name
To Node Element To Node name
Link Suffix InfoWorks adds a suffix for each parallel link.
Asset ID Valve name
Local Loss Coefficient Coefficient
Length

Set to default value by InfoWorks: 1.0m

Diameter Diameter
Friction Type Set to default value by InfoWorks: DW
DW - f Set to default value by InfoWorks: 0.015
Valve Diameter Diameter
Valve Curve Set to default value by InfoWorks: DefaultFLV
Regulation Type

Continuous if a profile is specified or if the regulating range (see below) is 0.

On/Off if no profile.

Opening (%) Valve Tau is converted to opening.
Regulating range Imported from Synergi.
Inlet level Elevation of From Node.
Backfeed pipe Set to default value by InfoWorks:
  • No for Synergi tank fill valves.
  • Yes for other valves.

Control Depth

(control data)

If a valve profile is specified in Synergi:

Top water level – first X value in valve profile. (X valves in Synergi specify the drop from the top of the reservoir).

If no profile is specified:

Top water level – bottom water level

Initially Open

(control data)

Open if initial position > 0.5.

Closed if initial position <= 0.5.

Notes Element description

Nodes

IWWS Data Field Values imported from Synergi
Node ID Node Name
X X coordinate for node
Y Y coordinate for node
Elevation Node Elevation
Notes Node Description

Fixed Heads

Nodes are imported as fixed head nodes if they have a known pressure and they are not a control node for a valve or a pumping station. If the fixed head nodes have demand in Synergi then the demands are not imported because fixed head nodes in InfoWorks cannot have demand.

IWWS Data Field Values imported from Synergi
Node ID Node Name
X X coordinate for node
Y Y coordinate for node
Elevation Node Elevation
Constant Head If head is fixed: Node PressureorHGL value + Node Elevation
Head Profile If head is variable:
  • Date-time set from Node Profile X value
  • Head values set from node profile Y value + Node Elevation
Notes Node Description

Transfer Nodes

Nodes are imported as transfer nodes if they have negative demand. If the transfer node has more than one demand category only the first category will be imported.

IWWS Data Field Values imported from Synergi
Node ID Node Name
X X coordinate for node
Y Y coordinate for node
Elevation Node Elevation

Flow Factor

(control data)

Set to default value by InfoWorks: 1

Head Profile

(control data)

Date-time set from Node Profile X value

Head values set from node profile Y value

Notes Node Description

Reservoirs

IWWS Data Field Imported Values
Node ID Name of Tank From Node
X X coordinate of Tank From Node
Y Y coordinate of Tank From Node
Elevation Elevation at Tank From Node
Bottom Reservoir Level Elevation of Tank From Node + Tank Bottom value.
Top Water Level Elevation of Tank To Node
Depth/Volume profile Imported from Synergi Profile X and Y. Depths below 0.20 m and volumes below 1.0 m3 are not imported.
Notes Tank element Description

Initial Depth

(control data)

Tank Level of Tank element

Pumps

IWWS Data Field Values imported from Synergi
Pump ID Imported from Synergi
Nominal Flow Calculated by Infoworks: Average flow from head-discharge profile.
Nominal Speed Pump Rated Speed
Suction Diameter Calculated by InfoWorks: Nominal value based on a diameter calculated from the nominal flow and a velocity of 4 m/s.
Pressure Diameter Calculated by InfoWorks: Nominal value based on a diameter calculated from the nominal flow and a velocity of 4 m/s.
Q-H-P curve
  • Q set from Synergi profile X value.
  • H set from Synergi profile Y value.
  • P calculated by InfoWorks from Q and H, assuming a constant efficiency of 80%.

Pump Stations

IWWS Data Field Values imported from Synergi
From Node Name of element From Node
To Node Name of element To Node
Link Suffix InfoWorks adds a suffix for each parallel link
Asset ID Pump name
Length Set to default value by InfoWorks: 1.0m
Diameter Set to default value by InfoWorks: 555 mm
Friction Type Set to default value by InfoWorks: DW
DW - f Set to default value by InfoWorks: 0.015
Power Factor Set to default value by InfoWorks: 0.9
PST Duty Head First value from head-discharge profile or 0.0.
Electrical Mechanical Power Ratio Set to default value by InfoWorks: 1.25
Voltage Set to default value by InfoWorks: LOW
Duty flow Set to default value by InfoWorks: 99 l/s
Local Loss Coefficient Set to default value by InfoWorks: 0.0
Tariff Name Set to default value by InfoWorks: M3

Mode Of Control

(control data)

  • If a control node is specified and the set pressure is specified, control mode is PROF.
  • If a time-speed profile is specified, control mode is PLAN.
  • If a control node is specified and a level, control mode is AUTO.
  • If a speed is specified, control mode is PLAN.
  • Otherwise the Mode of Control is not set.

Target Deviation On

(control data)

Set to default value by InfoWorks: -1.0m (for PROF pumps)

Target Deviation Off

(control data)

Set to default value by InfoWorks: 1.0m (for PROF pumps)

Target Pressure Depth

(control data)

Derived by InfoWorks from set pressure (for PROF pumps).

Control Node

(control data)

Pump ControlNodeId
Minimum speed Minimum of rated speed, speed (if non-zero), and PumpMin (if non-zero).
Maximum speed Maximum of rated speed, speed (if non-zero), and PumpMax (if non-zero).
Notes Pump description

Was this information helpful?