Share

Cooling quality result derivation-yellow

This topic specifies the conditions under which an area of the Cooling quality result will appear in yellow.

An area of the Cooling quality result is yellow if none of the red conditions are true, and at least one of the following conditions is true.

  • The cooling time variance for the area is a value between -60% to -75% or +100% to +150% of the average time to cool for the entire part.
  • The Temperature variance result temperature range for the area is between 10 to 20 degrees C under or 10 to 20 degrees C over the average surface temperature for the entire part.

Was this information helpful?