To use the Simulation Compute Manager
In the following instructions, inside simulation-computeX, X should be replaced with SCM major release
To change the temporary working file path for Thin client
The following process updates the location of a temporary working path for Simulation Compute Manager. For this example, the new location will be referred to as /tmp/scmWorking
- It can be written to by the Simulation Compute Manager user.
- It is on a volume with sufficient capacity to hold the jobs that you plan to run.
- It is on a volume that is present when the Simulation Compute Manager starts (or will automount when needed).
- It is not accessible to other Simulation Compute Managers running on other hosts.
- It ideally survives a reboot of the machine.
Create the new location with the properties outlined above.
Stop any existing Simulation Compute Manager instances with
curl localhost:43500/terminateorcurl <hostname>:43500/terminate.Allow sufficient time for the processes to exit cleanly.
Make sure the SimulationCompute processes are terminated by calling
/sbin/pidof SimulationCompute. If a process IDs are returned, kill the all processes usingkill -9 '<process ID>'.Make sure the fs-harness process is terminated by calling
/sbin/pidof fs-harness. If a process ID is returned, kill the process usingkill -9 '<process ID>'Set the environment variable:
export -x SCM_WORKING=/tmp/scmWorkingStart the Simulation Compute Manager using:
$INSTALL_ROOT/opt/Autodesk/simulation-computeX/bin/SimulationCompute
To change the Simulation Compute Manager Storage path for Thin client
The environment variable that changes the location of a storage path for Simulation Compute Manager is SCM_DATAPATH. The environment variable must be set prior to starting the Simulation Compute Manager. For this example, the new location will be referred to as /tmp/newlocation
Create the new location with the properties outlined above.
Stop any existing Simulation Compute Manager instances with
curl localhost:43500/terminateorcurl <hostname>:43500/terminate.Allow sufficient time for the processes to exit cleanly.
Make sure the SimulationCompute processes are terminated by calling
/sbin/pidof SimulationCompute. If a process IDs are returned, kill the all processes usingkill -9 '<process ID>'.Make sure the fs-harness process is terminated by calling
/sbin/pidof fs-harness. If a process ID is returned, kill the process usingkill -9 '<process ID>'Set the environment variable:
export -x SCM_DATAPATH=/tmp/newlocationStart the Simulation Compute Manager using:
$INSTALL_ROOT/opt/Autodesk/simulation-computeX/bin/SimulationCompute
Existing installations as workstation
Remove any existing installation of Moldflow Insight or Simulation Compute Manager from the machine and delete or remove /var/opt/Autodesk/SimulationCompute/vX/config. To uninstall and delete or remove this file, you would need root access.