There may not be enough available physical memory to complete the analysis. Ensure other programs are not running. Reduce the mesh density if necessary or run on a workstation with more memory.
This critical warning occurs during the mesh generation process, which includes an estimate of maximum memory usage for the simulation, indicating the simulation may exceed the system memory and will not complete successfully.
Running on an encrypted drive will increase simulation time. Consider solving on a non-encrypted drive to improve performance.
Running on a network drive will increase simulation time. Consider solving on an internal drive to improve performance.
Running on a USB drive will increase simulation time. Consider solving on an internal drive to improve performance.
These critical warnings are shown whenever the simulation is run on an encrypted, network, or USB drive. These drive types can cause small to significant increases in simulation time. It is recommended that users always simulate on a non-encrypted, internal drive, with the highest availed transfer and write speeds to ensure system performance does not artificially slow Netfabb Simulation .