Local Simulation
- If users switch from multiple displays to a single display, dialogue menus may appear off screen. To fix the issues reinstall Local Simulation.
- The sort function in the PRM Library is not effective for PRM type, Interlayer Temperatures, and Last Modified columns.
- Lack of Fusion and Hotspot only type PRMs will be erroneously labeled failed if given a name containing unicode characters.
- TIVUS files with names containing more than one period (.) cannot be used to create warped STLs in Local Simulation. Use a different filename, or use the distort_stl tool to warp files from the command line in Local Simulation.
- If a DED mesh preview is made and then the mesh settings are changed before solving, the Mesh in the preview will not match that observed in the simulation results.
- Closing the results Table in the DED workspace will turn off Warp by Displacement. Users can manually restore visual warping of the results from the Plot Settings menu.
- Importing STL files into
Local Simulation on a Windows 7 Remote Desktop produces a crash. As a workaround, you can launch
Local Simulation from a command line with the following command:
tscon 1 /dest:console start "appname.exe modelfile.stl" where
modelfile.stl is the name of the file to be imported. If this does not work, a more extensive procedure is as follows:
Determine your remote desktop session ID
- At the Command prompt, type
query session and press Enter.
- Find the ID number in the rdp-tcp row (typically 1 or 2).
Create and run a batch file
- In a text editor, create a two-line batch file (.bat) with the correct Session ID,
Netfabb install directory, and STL file path. These elements are located as shown below:
tscon <session ID> /dest:console start "" "<Netfabb install directory>\SIM\appbase.exe" "<STL file path>" ""
An example is as follows:
tscon 1 /dest:console start "" "C:\Program Files\Autodesk\Netfabb Ultimate 2020\SIM\appbase.exe" "c:\test\1.stl" ""
- Run the batch file as an administrator.
Note: The batch file will end by logging you out of the remote desktop connection. Log back in to see the imported STL file in Simulation Utility.
- At the Command prompt, type
query session and press Enter.
- Local Simulation does not work if Netfabb is installed in a folder whose name contains international characters.
- When working with a part that contains "model" in the name, Local Simulation will crash when you perform a mesh preview or a solve. The error is caused because Local Simulation incorrectly writes multiple STL files to the *STLF keyword. As a workaround, rename the part so that it does not contain the text "model".
- Warning and error notifications are cleared from the list of toast notifications when a simulation is re-run.
- If a part level powder bed or DED model is run while a PRM generation process is in progress, critical warnings and error notifications for the PRM process are not shown. Warnings and errors for a PRM generation are available from the View Logs button within the Job Manager.
- If multiple PRM files are generated simultaneously, the Lack of Fusion, Hot Spot, and Interlayer temperature columns in the Processing Parameters Library can remain blank until the Local Simulation is closed and restarted.
- Selected points from the Results Probe will be lost once the user closes the Table window.
- Some .SLDPRT files will not import the first time. If the user re-attempts the import it will work correctly.
- The new splashscreen that appears upon opening Local Simulation may not be fully visible on smaller screens at some resolutions.
Local Simulation
- The first time you solve from the command line, you may receive a message saying "'pan' is not recognized as an internal or external command, operable program or batch file." As a workaround, edit the Path environment variable (NetfabbSimulation 2021\Solver\bin). ) to point to the bin directory of the Local Simulation installation (typically C:\Program Files\Autodesk\
- Be sure to set the environment variables in netfabb_sim_vars.sh according to your system. Refer to the Shell and Intel MKL Environment Variables section of the help for details about controlling the number of threads and the memory limit per thread. If these variables are not set in accordance with your system, a segmentation fault can occur.
- Unconstrained DED toolpaths will create unconstrained floating elements and incorrect results.