Terminal Plan Data Fields to Report Dialog Box

Specifies which fields to include in the report, the field order, and the field labels.

Find

Command entry: AESCHEMATICREPORT

Select Terminal Plan from the report list. Run the report and click Change Report Format on the Report Generator dialog box.

List of Options

The following options are displayed.

Available Fields
Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
Fields to Report
Specifies the fields to display in the report, and the field order.
Remove
Removes the selected field from the Fields to Report list.
Remove All
Removes all the fields from the Fields to Report list.
Move Up
Moves the selected field up one spot in the Fields to Report list.
Move Down
Moves the selected field down one spot in the Fields to Report list.
Change Field Name/Justification
Specifies the field label and justification for the selected field.
Note: The vertical justification is used only when the report is inserted as a table.

Available Fields

Each line item in the report can include two connected components, referred to as the From and To components. Whether a component is considered the From or the To component is based on the wire sequence for the wire network. The wire sequence can be defined specifically or can default to the Tag/Wire Number/Wire Sequence Order defined on the Drawing Format tab of the Drawing Properties dialog box. The From field labels end in a "1" and the To field labels end in a "2".

INST1
Installation value on the From component
LOC1
Location value on the From component
CMP1
Tag value on the From component
PIN1
Terminal number on the wire connection attribute of the From component
PD1
TERMDESC value on the wire connection of the From component
LAYCMP1
Layer of the wire connected to the From component
CBL1
Cable tag on the wire connected to the From component
CBLWC1
Cable wire or cable core color connected to the From component
WNUM1
Wire number on the wire connected to the From component
LAYTRM1
Layer of wire connecting the From component to the terminal
STRIP-ID
Tagstrip value for the terminal
TD1
TERMDESC value on the wire connection of the terminal connecting to the From component
TERM
Terminal number
TD2
TERMDESC value on the wire connection of the terminal connecting to the To component
TINST
Installation value on the terminal
TLOC
Location value on the terminal
LAYTRM2
Layer of wire connecting the To component to the terminal
WNUM2
Wire number on the wire connected to the To component
CBL2
Cable tag on the wire connected to the To component
CBLWC2
Cable wire or cable core color connected to the To component
LAYCMP2
Layer of the wire connected to the To component
PD2
TERMDESC value on the wire connection of the To component
PIN2
Terminal number on the wire connection attribute of the To component
CMP2
Tag value on the To component
INST2
Installation value on the To component
LOC2
Location value on the To component
SH
Sheet value (%S) for the drawing where the terminal is located
REF
Line reference, X-Y Grid, or X Zone location of the terminal
HDL
Entity handle value of the terminal block
XDIR1
Wire connection direction code and suffix for the From component
XDIR2
Wire connection direction code and suffix for the To component
DWGIX
DWGIX value, as listed in FILETIME table of project database, for the drawing where the terminal is located
W01USER1-W10USER1
Attribute values from the wire number block on the wire connecting the From component
W01USER2-W10USER2
Attribute values from the wire number block on the wire connecting the To component