PLC I/O Address and Descriptions Data Fields to Report Dialog Box
Specifies which fields to include in the report, the field order, and the field labels.
Find
Command entry: AESCHEMATICREPORT
Select PLC I/O Address and Descriptions from the report list. Run the report and click Change Report Format on the Report Generator dialog box.
List of Options
The following options are displayed.
Available Fields
Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
Fields to Report
Specifies the fields to display in the report, and the field order.
Remove
Removes the selected field from the Fields to Report list.
Remove All
Removes all the fields from the Fields to Report list.
Move Up
Moves the selected field up one spot in the Fields to Report list.
Move Down
Moves the selected field down one spot in the Fields to Report list.
Change Field Name/Justification
Specifies the field label and justification for the selected field.
Note: The vertical justification is used only when the report is inserted as a table.
Available Fields
TAGNAME
PLC symbol or module's tag value
ADDR
PLC I/O point's address
TERM
PLC I/O point's terminal number
PD1
PLC I/O point's terminal TERMDESC value
DESCA-DESCE
PLC I/O point's five description values
LREF
Line reference, X-Y grid reference, or X Zone reference of the PLC symbol or module
WIRENO
Wire number
INST
Installation value
LOC
Location value
MFG
Manufacturer or vendor name
CAT
Catalog part number assignment
ASSYCODE
Assembly code value linking the catalog value to subassembly items
LINE1
PLC module's LINE1 attribute description text
LINE2
PLC module's LINE2 attribute description text
HDL
Handle number of the PLC symbol or module block
XTERMHDL
Entity handle number for the X?TERMxx wire connection attribute
TERMCODE
Wire connection X?TERMxx attribute suffix (the "xx")
SH
Sheet value (%S) for the drawing where the PLC symbol or module is located
SHDWGNAM
Drawing value (%D) for the drawing where the PLC symbol or module is located
IEC_P
Project value (%P) value for the drawing where the PLC symbol or module is located
IEC_I
Installation value (%I) value for the drawing where the PLC symbol or module is located
IEC_L
Location value (%L) value for the drawing where the PLC symbol or module is located
SEC
Section value for the drawing where the PLC symbol or module is located
SUBSEC
Sub-section value for the drawing where the PLC symbol or module is located
DWGIX
DWGIX value, as listed in FILETIME table of project database, for the drawing where the PLC symbol or module is located