Component Wire List Data Fields to Report Dialog Box

Specifies which fields to include in the report, the field order, and the field labels.

Find

Command entry: AESCHEMATICREPORT

Select Component Wire List from the report list. Run the report and click Change Report Format on the Report Generator dialog box.

List of Options

The following options are displayed.

Available Fields
Lists the available fields for the report, including fields added with the User Attributes command. Select a field from the list to add it to the report.
Fields to Report
Specifies the fields to display in the report, and the field order.
Remove
Removes the selected field from the Fields to Report list.
Remove All
Removes all the fields from the Fields to Report list.
Move Up
Moves the selected field up one spot in the Fields to Report list.
Move Down
Moves the selected field down one spot in the Fields to Report list.
Change Field Name/Justification
Specifies the field label and justification for the selected field.
Note: The vertical justification is used only when the report is inserted as a table.

Available Fields

WIRENO
Wire number
PIN
Terminal number on the wire connection attribute of the component
TAGNAME
Component tag value
LOC
Location value
WLAY
Layer of the wire connected to the component
P1C2
A value of 1 indicates the component is a parent symbol, a 2 indicates the component is a child symbol
REF
Line reference, X-Y grid reference, or X Zone reference of the component
SH
Sheet value (%S) defined in the drawing properties
SHDWGNAM
Drawing value (%D) for the drawing where the component is located
BLKNAME
Block name
HDL
Handle number of the component block
XTERM
Wire connection X?TERMxx attribute suffix (the "xx")
CBL
Cable tag
CBLWC
Cable wire or cable core color
NONC
Contact attribute value; Normally Open (NO) or Normally Closed (NC) contact state
SEC
Section value for the drawing where the component is located
SUBSEC
Sub-section value for the drawing where the component is located
TERMDESC
TERMDESC value on the wire connection of the component
INST
Installation value
DESC1-3
Description 1-3 values on the component
MFG
Manufacturer or vendor name
CATALOG
Catalog part number assignment
ASSYCODE
Assembly code value linking the catalog value to subassembly items
RATING1-12
Rating 1 - 12 values
XTERMHDL
Entity handle number for the X?TERMxx wire connection attribute
XDIR
Wire connection direction code and suffix for the component
DWGIX
DWGIX value, as listed in the FILETIME table of the project database, for the drawing where the component is located
W01USER-W10USER
Attribute values from the wire number block