External Passive Cooling

The thermal performance of many passively cooled devices depends on the interaction with the external environment. Unlike actively cooled devices in which an internal fan dominates the cooling, passively cooled devices are cooled through the movement of air outside of the device. To simulate this interaction, an air region is constructed completely around the device.

The air region within the device will be quite small relative to this external volume. In most cases, however, it should be included in the model. The device can be sealed so that this region is disconnected from the outer region, or it can be vented, allowing air to pass from the environment through the device.

As in the other passively cooled configurations, buoyancy is the dominant mechanism of heat transfer. Conduction from heated components to the case is also important, so it is good practice to ensure that physical links are modeled to provide adequate conduction paths.

Applications

Projector on a table

ATR box assembled at the base

TV or monitor on a table or TV stand

Router, hard-drive, inverter resting on a table or platform

Telecommunications module or transformer suspended from a utility line or pole

Thermostat mounted to a wall

Suspended lighting fixture

Modeling Strategy

There are three primary modeling strategies based on the placement of the device relative to its surroundings: Table-mounted, Air-mounted (such as on a pole or from a wire), and Wall-mounted.

Table-Mounted

Air-Mounted

Wall-Mounted

Materials

Boundary Conditions

Table-mounted

Air- and Wall-mounted

Mesh

A basic guideline for a high-quality analysis model is that the mesh distribution be sufficient to resolve the flow and temperature gradients efficiently. In regions where the flow circulates or experiences large gradients (such as in wakes, vortices, and separation regions), a finer mesh is required.

For most models, use Automatic Sizing to define the mesh distribution. It may be necessary to locally refine the mesh on geometric features that are highly detailed. For more information about Mesh Autosizing and model preparation...

In some cases, it may be necessary to adjust the Minimum Refinement Length to reduce their effect on the overall mesh count.

To locally refine the mesh in high-gradient flow regions:

Running

Results Extraction

Flow Distribution

Component Temperatures

For more general information, use the extensive collection of results visualization tools to extract flow and thermal results.

Troubleshooting

Air-mounted and Wall-mounted

Ideally, the flow should enter through the bottom surface of the region, curve around the device, and accelerate in a plume, as shown on the left. Flow should not enter from the top opening, as shown on the right:

   

If the flow does enter from the top, there are two recommended corrective actions:

  1. Apply a Film Coefficient boundary condition to the top surface. Specify the Film coefficient = 2 W/mK 2and Reference Temperature = ambient temperature + 1 degree.

  2. Refine the mesh above the fixture. A convenient method is to create amesh refinement region directly above the fixture. The flow gradients will be computed more accurately by focusing the mesh in this region.

  3. Reduce the Local stretching from 1.1 to 1.08. If the problem persists, reduce to 1.05:

  4. On the Mesh task, right click, and select Edit.

  5. On the Mesh quick edit dialog, click the Advanced button.

  6. Change the value in the Local stretching field.

Note: If one or both of these modifications is made to a scenario, apply the same modification to all scenarios. This ensures consistency across the entire design study.

Table-Based

Ideally the flow should enter from the sides of the opening, and exit through the center(forming the plume from the device), as shown on the left. Flow should not enter from just one side and exit near the other side, as shown on the right:

 

 

If the flow enters from one side and exits through the other, the recommended action is to refine the mesh above the fixture. A convenient method is to create a mesh refinement region directly above the device. The flow gradients are computed more accurately by focusing the mesh in this region.

Things to Avoid