Share

Controlling a VTR

Important: With Flame Family 2023, VTR capture and VTR output enter maintenance mode: they are no longer qualified or tested by Autodesk.

The RS-422 serial connection between the VTR and your workstation enables full remote control of the device from Flame. Connected VTR devices send their current status to Flame, and this status is displayed in the VTR Input and VTR Output modules.

Verifying the VTR Status

The following illustration shows a VTR status display.

(a) VTR Status  (b) VTR Timing  (c) Colour Space  (d) Bit Precision  (e) Control Mode  (f) Audio Sample Rate  (g) Audio Input/Output Type

Other VTR status values include.

VTR field:Indicates:
VTR StatusPlay, Play Lock, Stop, Jog, Fast Forward (FFW), Rewind (RWD), 3x, 4x, 8x, 15x, 30x. When the field is blank the VTR is disengaged.
VTR TimingThe video timing currently configured on the video device.
Colour SpaceThe colour space conversion method for both input and output of clips.
Control Mode (LOCAL, REMOTE, or REC INHIBIT)Whether the VTR is in Local or Remote control mode. Local appears in yellow when the VTR is in Local mode. In Local mode, the VTR cannot be controlled from Flame. You can switch the VTR between Local and Remote mode only on the VTR. Rec Inhibit implies REMOTE mode, but you cannot output to the tape.
Audio Sample RateThe audio sampling rate when you input or output from the VTR.
Audio Input/Output TypeThe source audio interface type when inputting and the destination audio interface type when outputting.
Bit PrecisionThe accuracy used (SDI bit depth) when transferring data. This cannot be changed.

Was this information helpful?