PBAR (Bar Element Property)

Description

The PBAR entry defines the properties of bar elements (CBAR entry).

Format

1 2 3 4 5 6 7 8 9 10
PBAR PID MID A I1 I2 J

Example

PBAR 40 5 4.5 2.9 5.45
Field Definition Type Default
PID Property identification number. Integer > 0 Required
MID Material identification number. See Remark 2. Integer > 0 Required
A Area of the beam cross-section. Real > 0.0 Required
I1 Area moments of inertia for bending in plane 1 about the neutral axis. Real > 0.0 Required
I2 Area moments of inertia for bending in plane 2 about the neutral axis. Real > 0.0 Required
J Torsional constant. Real or blank 0.0

Remarks

  1. PBAR entries must all have unique property identification numbers.
  2. PBAR entries may only reference MAT1 material entries.