To display the measured points of surface inspection groups in the CAD view, select View tab > View Options panel > Points button.
PowerInspect compares the measurement results to the CAD data and uses colour to indicate the deviation from the CAD data:
- Green points are within tolerance.
- Red points are above the tolerance band.
- Blue points are below the tolerance band.
To choose the type of display, click the arrow and select:
- Pins to display the points as coloured pins on the CAD model. For example:
- Confetti to display the points of the inspection group as coloured spots in the CAD view. For example:
To hide the inspection points, deselect the button.