Assign Pressure = 0 Pa to Outlets
Select the three outlets. You will likely have to rotate the model to access all of them:
Open the Boundary Conditions quick edit dialog in One of the following ways:
- Click Edit from the context toolbar:
- Click Edit from the Boundary Conditions context panel:
Type = Pressure
Unit = Pa; Pressure = 0
Click Apply