DWF Output - Complete option reference

When you Publish a file using the Complete option, the published content varies based on the file type as described in the following table.

Document type Condition DWF output - complete
Part (IPT) General The DWF file represents the current state of the model
  Sheet Metal If a folded model and flat pattern exists, the DWF file includes it
  iPart factory The DWF file includes all members and member table
  iPart member The DWF file represents the current state of the model
  Stress Analysis The DWF file includes the current state of the model with stress\constraint indicators and stress scale.
Document type Condition DWF output - complete
Assembly (IAM) General The DWF file includes the assembly with design views, positional representations, and enabled BOM views.
  iAssembly factory The DWF file includes all members and member table with design views, positional representations, and enabled BOM views..
  iAssembly member The DWF file includes the assembly with design views, positional representations, and enabled BOM views.
  Weldment The DWF file includes the assembly with design views, positional representations, enabled BOM views, weld beads, and weld symbols.
  LOD Master The DWF file includes the assembly with design views, positional representations, and enabled BOM views.
  LOD Non-Master Only the active LOD only publishes to DWF. However, all design views, positional representations, and enabled BOM views publish.
Document type Condition DWF output - complete
Presentation (IPN) General The DWF file includes all presentation views, animations, assembly instructions, and referenced assembly with complete contents.
Document type Condition DWF output - complete
Drawing (IDW, DWG) General The DWF file includes all sheets, tables, and referenced models with complete contents for the models.