Schematic Reports Dialog Box - Missing Bill of Material
Identifies parent or stand-alone components without catalog information.
Components that do not carry catalog information can be identified in two ways:
Show - uses temporary graphics to indicate components on the active drawing that do not carry catalog information.
Report - generates a report of schematic components that do not carry catalog information.
Show Missing Catalog
Find
Adds diamond shaped temporary graphics to mark components that do not carry catalog number assignments.
Command entry: AEMISSINGCATREPORT
Click Show.
Schematic Missing Bill of Material Report
The report can be accessed in two ways:
Find
Schematic Reports command
Command entry: AESCHEMATICREPORT
Select Missing Bill of Material from the report list.
Find
Missing Catalog Data command
Command entry: AEMISSINGCATREPORT
Click Report.
Missing Bill of Material is preselected from the report list.
List of Options
The following options are displayed.
Report Scope
Specify whether to process the project or the active drawing.
Category
By default, the report extracts schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Options
Include Components
Specifies to include schematic components.
Include Cable Markers
Specifies to include cable information in the report.
Include Connectors
Specifies to include connector information in the report.
Include Terminals
Specifies to include schematic terminal information in the report.
Installation Codes to Extract
Filters the information extracted for the report based on installation values.
All
Extracts all components regardless of installation value.
Blank
Extracts only those components that do not have an installation value.
Named Installation
Extracts only those components that have an installation value matching the value entered in the box. Wild-card characters are supported.
Drawing. Select one or more installation values from a list of values used on the active drawing.
Project. Select one or more installation values from a list of values used across the project.
Location Codes to Extract
Filters the information extracted for the report based on location values.
All
Extracts all components regardless of location value.
Blank
Extracts only those components that do not have a location value.
Named Location
Extracts only those components that have a location value matching the value entered in the box. Wild-card characters are supported.
Drawing. Select one or more location values from a list of values used on the active drawing.
Project. Select one or more location values from a list of values used across the project.
Freshen Project Database
Specifies to update the project database with the latest drawing information.
Format