This table contains pump efficiency data. This data is used at the time of running an Energy Management analysis. Refer to the section on Energy Management for more information.
ID - The Pump ID.
SPEED - Enter the Pump speed here..
TYPE - Refers to the Type of the Pump Efficiency curve. Choose between 0:Constant, 1:Quadratic and 2:Multi-Point Curve.
EFFICIENCY - For 0:Constant pumps only, enter the pump efficiency here.
CURVE - Specify the curve type for both 1:Quadratic and 2:Multi-Point Curve type pumps here.
Note: You may add rows to this table using the Insert
or the Append
icon. You may also delete rows from this table by using the Delete
icon. This may provide a quick method to assign Efficiency data to a number of pumps. Also it provides a means to edit Efficiency data on a global level on the fly.
![](https://help.autodesk.com/cloudhelp/ENU/INFWP-UserGuide/images/GUID-B0F27AC7-E895-437A-B98C-D2CFCA174C8F.png)
![](https://help.autodesk.com/cloudhelp/ENU/INFWP-UserGuide/images/GUID-71818FD0-664B-4AEA-9F01-4C0CEBE9C7BF.png)
![](https://help.autodesk.com/cloudhelp/ENU/INFWP-UserGuide/images/GUID-ED1A6976-534F-45C1-9EF6-8DA71705C8D7.png)