InfoAsset Manager assumes that most organisations will normally work with just one Manhole Survey coding scheme. For this reason the coding standard is applied at the Database level by default. However, it is possible to override the database coding standard on a per network basis.
InfoAsset Manager supports several different Manhole Survey coding schemes. The available coding schemes are:
- EU (Assessment of drains and sewer systems, European Union Standard EN13508-2:2000)
- EU2011 (Assessment of drains and sewer systems, European Union Standard EN13508-2:2003+A1:2011)
- MACP (NASSCO Manhole Assessment and Certification Program (US))
- MSCC (Manual of Sewer Condition Classification from WRc)
- CH2M HILL SCREAM™ - Sewer Condition, A CH2M HILL Technology
- WSAA (Water Services Association of Australia)
Details of these coding schemes can be found in the table below.
EU |
EU2011 |
MACP |
MSCC |
CH2M HILL SCREAM™ |
WSAA |
|
---|---|---|---|---|---|---|
File Format |
Flat files (language dependent) |
XML CSV |
Microsoft Access (as defined by MACP) |
Examiner |
- |
- |
Codes |
EU |
EU2011 |
MACP |
MSCC |
CH2M HILL SCREAM™ |
WSAA |
Scoring Scheme |
- |
- |
MACP |
- |
CH2M HILL SCREAM™ |
- |
Current Supported Version | EN13508-2:2003 EN13508-2:2004 | EN13508-2:2003+A1:2011 | v4.2.1 – v7.0.8 | v4.0 | version dated 28th August 2006 | WSA05-2002 |
To change the current Manhole coding standard for the database:
- Select Database management
Standards & choice lists from the File menu (available when no networks are open). This displays the Standards and Choice Lists dialog.
- In the Manhole Standard box, select the Manhole Standard to be applied to this database.
- Click OK to apply changes.
To change the current Manhole coding standard for the current network:
- Select Standards & choice lists from the Network menu to display the Standards and Choice Lists dialog.
- In the Editing Standards & Choice Lists For section select the Network option. If there is no Network option, click Override to create new settings for the current network.
- In the Manhole Standard box, select the Manhole Standard to be applied to the current network.
- Click OK to apply changes.
Manhole Standard Choice Lists
Most choice lists can be edited in the Standards and Choice Lists dialog. By default, choice lists defined by the selected Manhole Standard are read only. The read only status of these choice lists can be overridden, allowing existing choices to be edited and user defined choices to be added.
See the User Defined Choice Lists topic for more information.