Solver message 301741
Message Text
** WARNING 301741 ** The critical shear stress xxx specified for wall slip is outside the typical range of 0.001 to 2 MPa. Analysis with wall slip on may encounter convergence difficulty.
Explanation
The value you have entered for the critical shear stress (
) in the Wall slip parameters dialog is outside of the expected range.
Resolution
Enter a value inside the expected range, or use 0.1 which is the default value. To do this:
- Click
(Home tab > Molding Process Setup panel > Process Settings. - In the Process Settings Wizard dialog, click Next if necessary until you find the Advanced options button.
- Click Advanced options.
- Click Edit associated with the Solver parameters.
- Click Edit wall slip parameters, and enter a different value for the critical shear stress (
).