Share

viewfactorupdate

Summary: Change how often view factors are computed for motion analyses.

Flag

ViewFactorUpdate A

A = percentage of the maximum diagonal that a moving object covers before view factors are updated.

Description

When radiation is enabled in a motion simulation, view factors are automatically recomputed when the moving part has traveled 2% of the maximum diagonal of the domain bounding box.

Use this flag to change how often the view factors are updated.

For more about solving radiation with motion simulations...