While probe path colours in the CAD view and verification status icons in the inspection sequence highlight the fault type of the first fault detected in a probe path, you can see more detailed information about probe path verification faults using the Info tab.
To view verification faults in the Info tab:
- In the inspection sequence, select the item you want to check.
- Click the Info tab, and display the Probe Path Faults. The area shows:
- the verification status of the item, such as Unverified, Unknown, Faults found, or No faults found.
- the type of any faults, such as Bad contact, Move outside boundary or Collision.
- the start and end locations of the moves.
For example:
Up to ten faults can be reported for each item. If more than ten faults are found, the tab displays More faults, but does not show the details.