Share

Solver message 129104

Message text

** ERROR 129104 ** The machine screw diameter is not specified. Check the process settings and run the analysis again.

Explanation

The machine screw diameter has not specified for the selected injection molding machine.

Note: This message is also given if you have entered a negative number.
Note: For multi-barrel analyses, injection molding machine may also refer to the sub-barrel set up.

Resolution

  • If the injection molding machine is from the System database (supplied with Autodesk Moldflow Insight), report the problem to datafittingmoldflow@autodesk.com.
  • If the injection molding machine is from a personal database (user-defined), go to (Analysis > Process Settings Wizard), and click Advanced options.... Click the Edit...button associated with Injection molding machine and enter the screw diameter for the machine.

Was this information helpful?