Solver message 99362
Message text
** ERROR 99362 ** The mechanical property data for the current material has the wrong number of coefficients. Define all mechanical model constants (E1, E2, v12, v23, G) and run the analysis again.
Explanation
The wrong number of coefficients are defined for the polymer mechanical property.
Resolution
- Edit the current material and specify missing mechanical properties.
- Select a different material.
- If the material is from the Autodesk Moldflow materials database, contact Technical Support.