Solver Message 99464
Message text
** WARNING 99464 ** The ratio of the composite elastic modulus in the first principal direction to elastic modulus in the second principal direction (E1/E2) value ( composite E1 E2 ratio ) is higher than the fully aligned E1/E2 ( fully aligned E1 E2 ratio ) value. Check the material data and run the analysis again.
Explanation
The fiber orientation prediction code has calculated the ratio of theoretical maximum elastic modulus in 1st principal direction (E1) value to theoretical minimum elastic modulus in 2nd principal direction (E2) value, if all fibers are aligned with the flow direction (
Resolution
- Edit the current material and change the composite elastic moduli.
- Select a different material.
- If the material is from the Autodesk Moldflow materials database, contact Technical Support.