Share
 
 

E5088

E5087 WARNING: E5088 MAXIMUM STATIC LOAD REACHED USING NONLINEAR MATERIAL SPECIFIED
Cause: A nonlinear static analysis was performed with one or more of the following nonlinear materials: CONCRETE, NITINOL, CREEP, or PLASTIC (field 4 MATS1 Bulk Data entry). The user applied load exceeded the material capability and the analysis terminated.
Action: Investigate the model for the following issues:
  • Check that the nonlinear material parameters specified on the CONCRETE, NITINOL, CREEP, or MATS1 Bulk Data entry(s) and any associated TABLES1 entries referenced are valid and reasonable.
  • Check that the model loading is reasonable and lower if necessary.
  • Check the element quality in areas where the nonlinear material is active.

Note that if results are desired at the point of termination, field 9 of the NLPARM Bulk Data entry must be set to ALL.

Remarks: See Autodesk Nastran Reference Guide, Section 4, Bulk Data, for entry format.