Share
 
 

E5072

E5072 WARNING: E5072 ACCEPTING INCOMPLETE CONVERGENCE AND MOVING TO NEXT INCREMENT
Cause: The bisection limit specified on the NLPARM (static solutions) or a TSTEPNL (transient solutions) Bulk Data entry for the current load increment has been reached (default 5) and PARAM, BISECT was set to OFF (default ON). The nonlinear solution sequence will continue with incomplete convergence for that increment/step and the bisect limit will be reset.
Action: None unless the solution continues to have trouble converging and bisects after this point. Otherwise increase the bisection limit and/or investigate the reason for the lack of convergence. See message E5075.
Remarks: See the Bulk Data section for entry format and the Parameters section for parameter format.

Was this information helpful?