Share
 
 

E5125

E5125 FATAL ERROR: E5125 DESIGN OPTIMIZATION NOT DEFINED PROPERLY, STATUS: n
Cause: A topological design optimization was not defined properly. The status codes have the following meaning:
Code Meaning
1 No topological elements defined.
2 One or more topological elements defined in multiple design spaces.
3 One or more elements collocated in the design space.
4 OCM engine maximum permitted iterations exceeded.
5 Mode number specified does not exist.
6 Unable to set up Automated Inertial Relief.
7 Zero stress in design space when stress is defined as an objective.
8 Dependent/independent design space mismatch.
9 Dependent/independent TOPTXPRCSMODE directive mismatch.
10 Dependent/independent enclosed non-design space mismatch.
11 Dependent/independent data exchange mismatch.
12 Incomplete discrete variable list.
13 PSHELL and element variable thickness both requested in the same TOPVAR.
14 TOPVAR PTYPE field must be PSHELL for PSHELL or element variable thickness.
15 TOPTMINESHLTHK parameter value greater than PSHELL thickness field.
16 LINK continuation PID field references an undefined property.
Action:
Perform the following, depending on the status code given:
Code Meaning
1 Correct the TOPVAR Bulk Data entry property reference.
2 Correct the TOPVAR Bulk Data entry property reference.
3 Remove the duplicate topological element(s) from the design space.
4 Correct the TOPVAR Bulk Data entry parameters.
5

Correct either the EIGRL or DRESP1 Bulk Data entries.

6 All solid and/or shell elements cannot be in the design space.
7 Correct model loading or boundary conditions.
8
  • When the TOPTXPRCSMODE directive is set to 0, correct the dependent TOPVAR Bulk Data entry (s) to match independent. The design space size and element type must match.
  • When the TOPTXPRCSMODE directive is set to 1, the independent design space size must be greater than or equal to the dependent.
9 Correct the dependent TOPTXPRCSMODE directive to match independent.
10 Correct the dependent enclosed non-design space to less than or equal to the independent enclosed non-design space.
11 Delete the associated .ODX and .ODD files and rerun the models.
12 Correct the DDVAL Bulk Data entry to have at least 2 discrete variables.
13 Correct the TOPVAR Bulk Data entry removing the ESHLX continuation.
14 Correct the TOPVAR Bulk Data entry PTYPE field.
15 Correct the TOPTMINESHLTHK value to be less than the PSHELL thickness.
16 Change the LINK PID field to an existing property identification number.
Remarks: None.

Was this information helpful?