TVD Connector Data Fields (SWMM)

TVD Connector data can be edited on either the TVD Connector Grid Window of the Polygons Grid or the TVD Connector Property Sheet.

The following describes all the data which can be used to define a TVD Connector.

Fields that are common to the majority of objects can be found in the Common Fields topic.

TVD Connector Data

Database Table Name: sw_tvd_connector

Field Name

Help Text

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

ID

Unique identifier for the TVD connector.

If the TVD connector is to be used to control a regulatory object such as a pump, the ID should be the same as the time series in the relevant the SWMM Control Rule.

id Text 64 0
Category

Optional user-defined category.

category_id Text 64 0
X coord X coordinate of the object. x Double XY 2
Y coord Y coordinate of the object. y Double XY 2
Area Area covered by the TVD connector. Default area is calculated from polygon geometry if the TVD connector is a polygon, or set to null if TVD connector is a point. area Double CA 3
Input A units type The data measurement type for Input A. input_a_units Text 8 0
Input A

This may be one of the following:

  • ID of a data stream in a scalar TSD.

    When referring to a data stream in a time series data, prefix the ID with a '#'. e.g. #datastream1.

  • ID of another TVD connector.
  • A numerical constant. This should not be the same as the ID of another TVD connector

If a number is specified, InfoWorks ICM first checks if it matches any existing TVD connectors IDs. If it does, then InfoWorks ICM uses that TVD connector as the input. If not, the software treats the number as a constant with units determined by the Connector units field.

input_a Text 64 0
Input B units type The data measurement type for Input B. input_b_units Text 8 0
Input B

See Input A.

By default, inputs are used as a sequential data sources. For example, if a data stream is specified in Input A and it has missing values, the Input B data stream will be used to fill the gaps.

However, this field may also be simultaneously, for example, in an SQL expression.

input_b Text 64 0
Input C units type The data measurement type for Input C. input_c_units Text 8 0
Input C

See Input A.

By default, inputs are used as a sequential data sources. For example, if a data stream is specified in Input A and Input B fields and both have missing values at the same timesteps, the Input C data stream will be used to fill the gaps.

However, this field may also be simultaneously, for example, in an SQL expression.

input_c Text 64 0
Output units type

The data measurement type for output from the TVD connector.

Note: Evaporation and temperature can be specified either as outputs of a TVD connector or as inputs to rainfall TVD connectors, but not both. If they do, the model will fail validation unless the Output units type field is left blank.
output_units Text 8 0
Connector units

Determines how any values calculated internally (by an explicitly-entered output expression or using inputs that are specified as numerical constants) should be converted into native units of the specified output type.

The options available in the dropdown list are populated when an Output units type is selected.

expression_units Text 32 0
Output expression

The SQL expression used with this TVD connector.

An expression can be specified using the SQL Expression dialog which is displayed by clicking on the button.

Note: The SQL functions and operators which can be used in the expression are listed in the TVD Connector - SQL Expression Dialog topic.

An expression can also be tested from the dialog.

output_expression Memo
Resampling buffer

The resampling buffer is the length (in minutes) of the additional period of input data prior to the run start time which must be captured in order to ensure that resampled values at and shortly after the run start time are correct.

It should be non-zero only if the TVD connector has an expression that uses the TSRESAMPLE function.

resampling_buffer Double 1 0 1800
Connected object type

Type of network object that the TVD connector is connected to.

connected_object_type Text 32 0
Connected object id

Enabled when Connected object type is set.

The ID of the network object that the TVD connector is connected to.

connected_object_id Text 66 0
Connection usage

Enabled when Connected object id is set.

Database Value

Description

Help Text
Input Input (default) The input to the TVD connector is used as an input to the network object specified in the Connected object id field.
Comparison Comparison

The input to the TVD connector will be available as results for comparison with the results of the network object specified in the Connected object id field.

An observed data trace will be displayed in pick graphs and graph reports.

usage Text 16 0
Input attribute

Enabled when Connection usage is set to Input and a Connected object id is set.

The data type of the data to be input to the connected network object.

input_attribute Text 16 0
Comparison result

Enabled when Connection usage is set to Comparison and a Connected object id is set.

The data type of the result data to be made available for comparison with the results of the connected network object.

comparison_result Text 16 0