Share
 
 

Manifest Validation Messages

Error and warning messages relating to the Manifest object are displayed in the Output Window when a manifest is validated.

Key to Messages

Left Column

The error message number is used internally by InfoWorks ICM. This number is unique, and may be useful when contacting Innovyze Support.

Centre Column

Name:

The error or warning message that is displayed.

Info:

Additional information about the error or warning, such as the name of the network object where the anomaly occurred

Cause:

Why the message has been displayed

Advice:

What, if anything, you need to do about it.

Right Column

Information only - no further action needed

Warning - action may be required

Error - action necessary

List of Validation Messages

The table below displays the list of validation messages that will be displayed in the Output Window. Click the message text for further information.

E0001

Alert definition ID defined in Action is not present in Alert definition list

Info

Action ID

Cause

An action in the Action list selected on the Actions page of the Manifest refers to an Alert definition ID that does not exist in the Alert definition list selected on the Setup page.

Advice

Review selected Action list and Alert definition list.

E2000

No default run present

Info

Run

Cause

No Default run has been specified.

Advice

Add a run to the Default Run droptarget of the Setup page.

E2001

%1: time fields should be in the form <n><u> where <n> is an integer and <u> is a unit specifier (d, h or m) (and %1 is the name of the invalid field in the schedule)

Info

Run schedule

Cause

The format of the data entered to specify time field is incorrect in the Setup page.

Advice

Enter the data using the <n><u> terminology.

E2002

Invalid alert definition list

Info

Alert definition list

Cause

The alert definition list has not been successfully validated.

Advice

Validate the offending alert definition list.

E2003

No archive folder present

Info

Archive folder

Cause

No Archive folder has been specified in the Archive section in the Maintenance page.

Advice

In the Archive section, select a Live Group to be the Archive folder.

E2004

Archive after days: The minimum value is 1 day

Info

Run maintenance

Cause

The value entered in the Archive after days field is invalid in the Maintenance page.

Advice

This field can only contain a positive integer (zero [0] and alphanumeric characters are not allowed).

E2005

Delete TVD results after days: cannot delete TVD results until they are archived

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete TVD results before they are archived (Value entered in the Delete TVD results after days field is equal to or less than the value entered in the Archive after days field).

Advice

Review the value entered in the Delete TVD results after days field in the Maintenance page.

E2006

The archive is already in use

Info

Archive folder

Cause

The Live Group specified in the Archive section of the Maintenance page is already used as an Archive folder by another manifest.

Advice

Change the Live Group specified in the Archive section. It is advised to use a different archive folder for each manifest.

E2007

The archive cannot be used because it is a descendant of another archive

Info

Archive folder

Cause

The Live Group specified in the Archive section of the Maintenance page is a child of a Live Group used as an Archive folder by another manifest.

Advice

Change the Live Group specified in the Archive section so it is not a child or a parent of a Live Group already used as an archive folder by another manifest.

E2008

The archive cannot be used because it is an ancestor of another archive

Info

Archive folder

Cause

The Live Group specified in the Archive section of the Maintenance page is a parent of a Live Group used as an Archive folder by another manifest.

Advice

Change the Live Group specified in the Archive section so it is not a child or a parent of a Live Group already used as an archive folder by another manifest.

E2009

Invalid action list

Info

Action list

Cause

The Action List specified in the Action page has not been successfully validated.

Advice

Validate the specified Action List.

E2010

Invalid path specified for CSV export

Info

Result export

Cause

The Enable export option has been checked in the Result CSV export page but no path to the export directory has been specified, or a path that does not exist has been specified.

Advice

Type in or select a path for the export directory in the Target box in the Result CSV export page.

Tip: The export directory specified in the Target field is used by the following export processes - export of results to CSV and export graphs and maps to PNG.

E2011

Invalid path specified for Graph and Map export

Info

Result export

Cause

The Enable map export option has been checked in the Map export page and/or the Enable graph export option has been checked on the Graph export page, but no path to the export directory has been specified, or a path that does not exist has been specified in the Map export or Graph export pages or in the Result CSV export page.

Note: The Target path in the Result CSV export page is used by Map export and Graph export if no path is specified in their pages.

Advice

Check, and if necessary correct, the path specified in the:

E2012

Custom graphs on the '<tab name>' tab should be based on the default sim

Info

Custom Graph

Cause

This error may be caused by:

  • A Custom graph, selected in the Display page, uses a sim that is not the same as the sim specified in the Setup page.
  • The Enable graph export option has been checked in the in Graph export page, and a Custom graph has been selected that uses a sim that is not the same as the sim specified in the Setup page.

Advice

Review the Custom graph selected on the tab identified.

Review the simulations specified in the Custom graph.

E2013

No graphs selected for post event report

Info

Event report

Cause

The Enable post event report option in the Post event report page is checked, but no custom graphs have been specified.

Advice

Select a custom graph in the Post event report page.

E2014

Exported graph size too small

Info

Event report

Cause

Size X and/or Y values in the Post event report page have not been specified.

Advice

Review the specified size values on thePost event report page.

E2015

Time window for run origins too narrow

Info

Event report

Cause

Run origin fields in the Post event reportpage are set to the same value.

Advice

Review the specified run origin values on the Post event report page.

E2016

Custom graphs on the 'Post event report' tab should be based on the default sim

Info

Event report

Cause

The Enable post event reportoption has been checked on the Post event report page, and a Custom graph has been selected that uses a sim that is not the same as the sim specified in the Setup page.

Advice

Review the Custom graph selected on the Post event report page.

Review the simulations specified in the Custom graph.

E2017

No database TSD

Info

Database export

Cause

No Scalar time series data object has been specified in the Database export page.

Advice

A Scalar TSD object is required. Drag and drop a Scalar TSD object onto the Scalar Time series data droptarget in the Database export page.

E2018

Data source not found

Info

Database export

Cause

A data source specified in the Data source field of the grid in the Database export page does not exist in the Scalar time series data object that has been associated with the manifest.

Advice

Ensure that the data source(s) specified in the Database export page exists in the Data Sources tab of the Scalar TSD object.

E2019

Database connection failed

Info

Database export

Cause

There is a connection issue with the database results are to be exported to.

Advice

Check that both the database name and location specified in the Filename / Foldername field of the Scalar time series data object match the actual name and location of the database results are being exported to.

E2020

Database table not found

Info

Database export

Cause

A database table specified in the Table name field of the grid in the Database export page does not exist in the Scalar time series data object that has been associated with the manifest.

Advice

Ensure that the database table(s) specified in the Database export page exist(s) in the database the results are to be exported to.

E2021

External field [External Field] not found in Table [Table name] in data source [Data Source Name ] for internal field [Internal Field].

Info

Database export

Cause

A database column (external field) that has been mapped to a InfoWorks ICM field in the Database Export Field Mapping Dialog does not exist in the database results are to be exported to.

Advice

Ensure that the database column(s) mapped in the Database Export Field Mapping Dialog exist(s) in the database the results are to be exported to.

E2022

Database is read-only

Info

Database export

Cause

The database results are to be exported to is of the wrong type.

Advice

Check that the database format is a supported type (PI, iHistorian and ClearSCADA types are not supported).

E2023

No baseline sim selected

Info

Run

Cause

A baseline simulation has not been selected in the Setup page.

Advice

Select a simulation in the baseline sim dropdown.

E2025

Delete full results after days: cannot delete full results until they are archived

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete full results before they are archived. (Value entered in the Delete full results after days field is equal to or less than the value entered in the Archive after days field.)

Advice

Review the value entered in the Delete full results after days field in the Maintenance page.

E2026

Delete full results after days: cannot delete full results until TVD results are deleted

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete full results before TVD results are deleted. (Value entered in the Delete full results after days field is equal to or less than the value entered in the Delete TVD results after days field.)

Advice

Review the value entered in the Delete full results after days field in the Maintenance page.

E2027

Delete run object after days: cannot delete run objects until they are archived

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete run objects before they are archived. (Value entered in the Delete run objects after days field is equal to or less than the value entered in the Archive after days field.)

Advice

Review the value entered in the Delete run objects after days field in the Maintenance page.

E2028

Delete run object after days: cannot delete run objects until TVD results are deleted

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete run objects before TVD results are deleted. (Value entered in the Delete run objects after days field is equal to less than the value entered in the Delete TVD results after days field.)

Advice

Review the value entered in the Delete run objects after days field in the Maintenance page.

E2029

Delete run object after days: cannot delete run objects until full results are deleted

Info

Run maintenance

Cause

InfoWorks ICM has been instructed to delete run objects before full results are deleted. (Value entered in the Delete run objects after days field is equal to less than the value entered in the Delete full results after days field.)

Advice

Review the value entered in the Delete run objects after days field in the Maintenance page.

E2030

Parent manifest is invalid. Please validate the parent manifest

Info

Manifest

Cause

The Parent manifest specified on the Setup page has not been successfully validated.

Advice

Validate the manifest specified in the Parent manifest field of the Setup page.

E2031

Cannot use the current manifest as a parent in the same manifest

Info

Manifest

Cause

The Parent manifest specified on the Setup page is the same as the current manifest.

Advice

Select a different manifest in the Parent manifest field in the Setup page.

E2032

Full run trigger: alert trigger does not exist as a category in the alert definition list

Info

Run schedule

Cause

The Full run trigger specified in the Run schedule on the Setup page does not match a category in the Alert definition list specified.

Advice

Set the Full run trigger to match one of the Alert definition list categories.

E2034

Variant run trigger: alert trigger does not exist as a category in the alert definition list

Info

Run schedule

Cause

The Variant run trigger specified in the Run schedule on the Setup page does not match a category in the Alert definition list specified.

Advice

Set the Variant run trigger to match one of the Alert definition list categories.

E2035

Full run trigger: an alert trigger has been specified without an alert definition list

Info

Run schedule

Cause

A Full run trigger has been specified in the Run schedule on the Setup page, but an Alert definition list has not been specified.

Advice

Select an Alert definition list on the Setup page.

E2037

Variant run trigger: an alert trigger has been specified without an alert definition list

Info

Run schedule

Cause

A Variant run trigger has been specified in the Run schedule on the Setup page, but an Alert definition list has not been specified.

Advice

Select an Alert definition list on the Setup page.

E2038

Run variants: Cannot choose to run variants when there is only one simulation contained in the default run

Info

Run schedule

Cause

The Default run specified on the Setup page contains one simulation and Run variants has been set to Always or Variant trigger.

Advice

Set Run variants to Never.

E2044

Ground model is required to export flood depths

Info

Export of flood depths to shape (shp) or image (png) files

Cause

A ground model grid has not been specified.

Advice

Add a ground model grid to the Ground model grid droptarget on the Map export page.

E2045

No theme for flood depth export

Info

Export of flood depths to shape (shp) or image (png) files

Cause

A theme has not been specified.

Advice

Add a theme for the flood object layer to the Theme droptarget on the Map export page.

E2046

Verification frequency has been specified without an alert definition list for verification

Info

Manifest

Cause

A verification frequency has been specified without an alert definition list for verification

Advice

E2047

Triggered verification frequency set without any alerts

Info

Manifest

Cause

A triggered verification frequency set without any alerts

Advice

.

E2048

The user defined run on device is not allowed because it uses a restricted device name

Info

Manifest

Cause

The user defined run on device is not allowed because it uses a restricted device name

Advice

E2049

Exports to PI should map timestep, and object id and only 1 attribute

Info

Database export field mapping

Cause

The required Date/time field, Object ID field and/or an attribute/internal field have not been specified.

Advice

Check that the Date/time field and the Object ID.(on the Info tab), and any internal field/attribute (on any other tab) have been specified. Note that the Date/time field must be set to Timestamp, and the internal field/attribute must be set to Value.

E2050

Exports to PI need a selection list

Info

Database export

Cause

The export of results to a PI WebAPI database requires a selection list. However, a selection list has not been included in the Selection List box on the Database export page.

Advice

Add a selection list and ensure that it contains the network objects whose time varying results are to be exported.

E2051

Internal field 'Date/Time' should map to the PI field 'timestamp'

Info

Database export field mapping

Cause

The Date/time field is not currently set to Timestamp.

Advice

Change the setting of the Date/time field (on the Info tab) to Timestamp.

W2000

No alert theme present, no alerts will be displayed

Info

Default theme

Cause

No default theme has been specified.

Advice

Add an alerts theme to the Default theme droptarget in the Display page.

W2001

No alert definition list present, no alerts will be displayed

Info

Alert definition list

Cause

No alert definition list has been specified.

Advice

Add an alert definition list to the Alert definition list drop target in the Setup page.

W2002

No areas of interest present, a default will be used

Info

Selection list

Cause

No area of interest selection list has been specified

Advice

Add an area of interest selection list to the Selection list drop target in the Display page.

W2003

An area of interest polygon does not exist in the network of the default sim

Info

Selection list

Cause

A selection list containing polygons from another network or another version of the network has been specified in the he Selection list droptarget in the Display page.

Advice

Ensure that the selection list corresponds to the correct network and to the same version of the network used in the associated simulation (Sim droptarget in the Setup page.

W2004

No library folder present

Info

Library folder

Cause

No Library folder has been specified in the Run Library section in the Maintenance page.

Advice

In the Run Library section, select a Live Group to be the Library folder.

W2007

Export is enabled for graphs and maps but none have been selected

Info

Map export / Graph export

Cause

No Custom Graphs in the Graph export page, or Maps in the Map export page, have been selected for export.

Advice

Ensure that at least one custom graph is selected for export in the Graph export page or one map is selected for export in the Map export page.

W2008

Run variants: Chosen to run variants with 'Variant trigger' but no variant run trigger has been specified

Info

Run schedule

Cause

Run variants in the Run schedule grid in the Setup page has been set to Variant trigger, but a Variant run trigger has not been specified.

Advice

Specify a Variant run trigger, or select another Run variants option in the Setup page.

W2009

Parent run trigger: A parent manifest has been specified without a parent run trigger

Info

Run schedule

Cause

A Parent manifest has been selected in the in the Setup page, but a Parent run trigger has not been specified in the Run schedule grid.

The parent manifest will never trigger the current manifest run schedule.

Advice

In the in the Setup page, set a Parent run trigger.

Was this information helpful?