Solver message 313405

Message text

** ERROR 313405 ** No injection nodes have been specified on the rotation elements of the first-shot mesh. Ensure that the part and feed system elements that are marked as rotation elements are connected to an injection node.

Explanation

This error is fatal. The solver could not find the injection location on the rotation elements of the first shot.

Resolution

  • Click Injection location in the study task pane, and set an injection location for the rotation elements of the first shot.
  • If the model has an injection location, ensure that the part and feed system elements for this model are marked as rotation elements.