Solver message 223063

Message text

** WARNING 223063 ** The Generic shrinkage model is selected for only one material in the overmolding analysis. This is not supported. The second material's shrinkage model will be switched to match the first material.

Explanation

In an overmolding process, you can assign a specific shrinkage model for each material. However, it's important to note that the solvers do not support the use of a generic shrinkage model for one material and a non-generic model, such as the uncorrected residual stress model or the STAMP model, for the other material. In such cases, the solver will automatically switch the shrinkage model of the second material to match that of the first material.

Resolution

No action is required.