Solver message 301553
Message text
** WARNING 301553 ** For thermoset warpage analysis in midplane/fusion, please check the followings. (1) Compressible solver is selected. (2) Material data (such as PVT and mechanical properties) are specified.
Explanation
For thermoset, check whether compressible solver is selected. Also check the material properties (such as pvT and mechanical properties).
Resolution
If using incompressible solver, switch to compressible solver. If some material properties are missing, provide missing material properties.