Solver message 702165
Message text
** WARNING 702165 ** No heat loss value specified for hot manifold element %7d, using default
Explanation
Hot manifolds are not perfectly insulated and conduct some heat into the surrounding mold. The value for Heat loss into mold has not been specified for the indicated element. The analysis has assigned the default value of 10W/m^2.
Resolution
Locate the element specified in the message using (Modeling > Query Entities), right-click on the element and select Properties, then enter a value for Heat loss into mold.